However we see from a few houses we visited staircase design home impressed very monotonous and boring because of the design of the first just so so only.
Door at bottom of stairs building regs.
I have a small barn conversion over 3 floors.
The diagrams below illustrate this.
The landing distance in front of the top and bottom step must be at least the width of the staircase.
Building regulations door at bottom of stairs the staircase is a very important element to a home that has more than one floor.
For loft conversions the headroom will pass the building regulations if the centre of the stair width is 1 9m reducing to 1 8m at the side of the stair.
Clear space should be provided at the top and bottom of flights of stairs measuring at least the width of the stair and this can be reduced to 400mm at the bottom of stairs within dwellings.
Uk building regulations stairs are no joke.
The space between any door opening and the staircase should be at least 400mm.
Resi s building regulations package.
Staircase building regulations are covered by further regulations parts m1 and m2.
Please note where there are real difficulties in the height some building control officers will allow you to build a newel out from the wall to meet the regulations.
9 open riser stairs.
It s the ground floor of a protected staircase and shows the door swing directly over the bottom of the stair within the landing space.
Building regs doors and stairs.
Landing at the top and bottom of every staircase should be level and flat although those at ground level can have a gradient as long as it doesn t exceed 1 20.
As an example if you want to build a regulation staircase all risers will have to come at the same size.
The building regulations stipulate that there must be 400mm from the door or swing of the door to the bottom of the stairs.
No door should swing closer than 400mm to the front of any step.
If it s that bad put the door at the bottom of the stairs instead.
An external window or door is a controlled fitting under the building regulations and as a result of this classification these regulations set out certain standards to be met when such a window or door is replaced.
The only exception is when you build a staircase where a landing separates two sets of flights.
But note that the landing requirement is the same for the top and bottom so the door has to be 1 step width away from the bottom step and open outwards or inwards no closer than 400mm.
Door at top of loft stairs building regulations.
In that case these two flights can have different rises compared to each other.
The regulations apply to thermal performance and other areas such as safety air supply means of escape and ventilation.
The ground floor is a kitchen stairs up to the first floor and a lounge ensuite spare room.
Landings must be clear of any permanent obstructions.